MaximaLabs
All guides
Solvents plant, Texas City, Texas, USA

How to simulate acetone from isopropanol dehydrogenation

Endothermic gas-phase dehydrogenation of isopropanol (IPA) to acetone, after Luyben (Ind. Eng. Chem. Res. 2011, 50, 1206). The H₂-rich reactor off-gas is scrubbed with water to recover the acetone before venting, then a column splits acetone from the water/unreacted-IPA absorbent.

FEED
Dehydro
Scrub Water
liq
gas
gas
rich
ABS
H2 VENT
feed
dist
btms
Qc
Qr
COL
Acetone Product
Water Bottoms
  1. 1
    Open the ready-made model

    Open the "Acetone from isopropanol dehydrogenation" model in the MaximaLabs workspace — no install, no license. It loads live on the canvas, ready to edit and run.

  2. 2
    Confirm the thermodynamics

    This process is modeled with the PENG-ROBINSON property package over isopropanol, acetone, water, h2 — already selected, so the phase equilibrium and enthalpy are physically consistent from the first run.

  3. 3
    Review the flowsheet

    The flowsheet chains Dehydro, ABS, COL. Every block is a real, solvable unit op you can reconfigure on the canvas.

  4. 4
    Run the simulation

    Click Run. The deterministic solver converges the material and energy balances (recycles included) and fills the live stream table — the AI never invents a number.

  5. 5
    Read the results and iterate

    Inspect the converged streams, tweak a spec, and re-run — or ask the AI copilot to explain a result or diagnose a failed solve in plain English.

What you'll build
Thermodynamics
PENG-ROBINSON
Components
isopropanol, acetone, water, h2
Unit operations
DehydroABSCOL
Open this model in the workspace

Opens live on the canvas — free, no install.

Explore the model & flowsheet

Frequently asked questions

What does the Acetone from isopropanol dehydrogenation model simulate?
Endothermic gas-phase dehydrogenation of isopropanol (IPA) to acetone, after Luyben (Ind. Eng. Chem. Res. 2011, 50, 1206). The H₂-rich reactor off-gas is scrubbed with water to recover the acetone before venting, then a column splits acetone from the water/unreacted-IPA absorbent.
Which thermodynamic method does it use?
The PENG-ROBINSON property package, over isopropanol, acetone, water, h2 — already selected. You can switch the method on the canvas before running.
Which unit operations are in the flowsheet?
It chains Dehydro, ABS, COL. Every block is a real, solvable unit operation you can reconfigure, add to, or remove.
Do I need to install software or buy a license?
No. Acetone from isopropanol dehydrogenation runs entirely in your browser on MaximaLabs — free, no install, no license. Open the model to load it live and run the deterministic solver.

More guides like this

Solvents plant, Texas City, Texas, USA

Methyl ethyl ketone from 2-butanol dehydrogenation

Catalytic dehydrogenation of 2-butanol to methyl ethyl ketone (MEK) over an In/MgO catalyst, per DE2831465A1 (1978), followed by a flash to remove the H₂ co-product and a distillation splitting MEK from unreacted 2-butanol.

Erlangen, Germany

LOHC hydrogen release (methylcyclohexane dehydrogenation)

A liquid organic hydrogen carrier (LOHC) power train: methylcyclohexane (MCH) is preheated and catalytically dehydrogenated (MCH → toluene + 3H2, endothermic, equilibrium-limited to ~90% single-pass conversion) to release hydrogen for downstream power generation. A flash drum separates the H₂-rich gas from the liquid; a distillation column then recovers the unreacted MCH overhead and recycles it to the reactor feed, closing a real tight liquid recycle loop, while spent toluene leaves the bottoms (to be re-hydrogenated back to MCH off-site, closing the supply-chain loop — out of scope for this dehydrogenation-side flowsheet). Screening-fidelity note: MCH and toluene are genuinely close-boiling (relative volatility ~1.4 under this thermo package at column conditions), so the recycle carries real toluene along with the recovered MCH rather than a sharp cut — a production column would use more stages to purify it further; this shows the recycle topology and its convergence, not an optimized column design.

Gas plant, Permian Basin, Texas, USA

Perry Ch.13 Example 2: lean-oil absorber

Simple absorber recovering butane and pentane from a process gas into a lean-oil (n-dodecane) absorbent, from Chapter 13 of Perry's Chemical Engineers' Handbook.

Gas plant, Permian Basin, Texas, USA

Perry Ch.13 Example 5: two-step absorber with intercooling

Two absorption stages in series with intercooling between them (removing the heat of absorption, which otherwise raises K-values and hurts recovery) to maximize LPG recovery, from Chapter 13 of Perry's Chemical Engineers' Handbook.

PDH complex, Baytown, Texas, USA

Propane dehydrogenation cold box

Propane dehydrogenation (PDH) to propylene over a Pt/Cr catalyst, followed by a cold-box separation recovering liquid propylene from the H₂-rich reactor off-gas, after US Patent 6,333,445 (Chart Inc., 2002). The refrigeration loop itself is not modeled — the cold box is represented here as a net cooling duty to condense the propylene, a bounded simplification. Unreacted propane recycle is not modeled either (reported as its own product stream).

Great Plains Synfuels Plant, Beulah, North Dakota, USA

CO2 removal from syngas (Rectisol-style physical solvent)

A CO₂-laden syngas stream from gasification/reforming (H₂/CO with 25% CO₂, the actual Rectisol duty — scrubbing raw syngas ahead of methanol/ammonia synthesis, not treating pipeline natural gas) is sweetened by a cold-methanol physical-solvent absorber (chosen because chemical amine reactions aren't modeled here) down toward synthesis-loop spec, then the rich solvent is regenerated by a pressure letdown into a second flash that flashes the bulk of the absorbed CO₂ back off — the same letdown-valve-plus-flash regeneration pattern used for HDA's and methanol synthesis's own dissolved-gas trains. No solvent recycle loop (an honest simplification: the regenerated solvent is reported as a product stream rather than closed back onto the absorber feed). From the ChemSep casebook (CO₂ removal from natural gas), adapted to Rectisol's real syngas duty.

Stop fighting legacy software. Build your first flowsheet in 60 seconds.