How to simulate propylene refrigeration (−30 °c)
Closed propylene cycle for −30 °C process cooling — the workhorse olefin-plant refrigerant. From the ChemSep casebook (Refrigeration_Propylene-30C).
- 1Open the ready-made model
Open the "Propylene refrigeration (−30 °C)" model in the MaximaLabs workspace — no install, no license. It loads live on the canvas, ready to edit and run.
- 2Confirm the thermodynamics
This process is modeled with the PENG-ROBINSON property package over propylene — already selected, so the phase equilibrium and enthalpy are physically consistent from the first run.
- 3Review the flowsheet
The flowsheet chains K0, JT0, 2× Evap0. Every block is a real, solvable unit op you can reconfigure on the canvas.
- 4Run the simulation
Click Run. The deterministic solver converges the material and energy balances (recycles included) and fills the live stream table — the AI never invents a number.
- 5Read the results and iterate
Inspect the converged streams, tweak a spec, and re-run — or ask the AI copilot to explain a result or diagnose a failed solve in plain English.
- Thermodynamics
- PENG-ROBINSON
- Components
- propylene
- Unit operations
- K0JT02× Evap0
Opens live on the canvas — free, no install.
Explore the model & flowsheetFrequently asked questions
- What does the Propylene refrigeration (−30 °C) model simulate?
- Closed propylene cycle for −30 °C process cooling — the workhorse olefin-plant refrigerant. From the ChemSep casebook (Refrigeration_Propylene-30C).
- Which thermodynamic method does it use?
- The PENG-ROBINSON property package, over propylene — already selected. You can switch the method on the canvas before running.
- Which unit operations are in the flowsheet?
- It chains K0, JT0, 2× Evap0. Every block is a real, solvable unit operation you can reconfigure, add to, or remove.
- Do I need to install software or buy a license?
- No. Propylene refrigeration (−30 °C) runs entirely in your browser on MaximaLabs — free, no install, no license. Open the model to load it live and run the deterministic solver.
More guides like this
Propylene refrigeration (−50 °C)
The same propylene loop pulled to −50 °C by sub-atmospheric evaporation (0.8 bar) — COP drops as the lift grows. From the ChemSep casebook (Refrigeration_Propylene-50C).
Ammonia refrigeration (−30 °C)
A closed single-stage ammonia vapor-compression cycle serving a −30 °C load: compressor → ambient condenser → JT valve → evaporator. The charge is set via tear_specs; metrics give duty and work (COP ≈ 2). From the ChemSep casebook (Refrigeration_Ammonia-30C).
Deep ethane recovery with propane-refrigerated feed chilling
Associated gas is chilled by an external propane refrigeration package before a demethanizer recovers ethane and heavier as NGL bottoms from a methane-rich residue gas overhead — the cryogenic-chilling role Ortloff's CCS/GSP processes play ahead of the turboexpander in a real deep-ethane-recovery plant. The mechanical refrigeration loop itself (compressor/condenser/valve) isn't separately modeled here; the chiller's duty is represented directly as the feed's cooled outlet temperature (the same honest-simplification pattern used for LNG cold-box examples elsewhere in this library).
Propane refrigeration cycle
A single-stage vapor-compression refrigeration loop: propane vapor is compressed, condensed to subcooled liquid, throttled through a valve, and superheated back to vapor in the evaporator before recycling — a small makeup feed and purge close the mass balance (inspired by ChemSep's Refrigeration_* reference cases).
Ammonia refrigeration cycle
A single-stage vapor-compression refrigeration loop using ammonia — the classic industrial (rather than HFC) refrigerant — condensed to subcooled liquid, throttled through a valve, and superheated back to vapor in the evaporator before recycling (inspired by ChemSep's Refrigeration_Ammonia-30C reference case).
Propane dehydrogenation cold box
Propane dehydrogenation (PDH) to propylene over a Pt/Cr catalyst, followed by a cold-box separation recovering liquid propylene from the H₂-rich reactor off-gas, after US Patent 6,333,445 (Chart Inc., 2002). The refrigeration loop itself is not modeled — the cold box is represented here as a net cooling duty to condense the propylene, a bounded simplification. Unreacted propane recycle is not modeled either (reported as its own product stream).