MaximaLabs
Back to gallery

Ammonia Process Flowsheets & Simulations

Explore 5 validated, solved Ammonia simulation flowsheets in MaximaLabs — real components: ammonia, h2s, water, n2, h2, argon. Open any one directly in your browser.

Solved via: COOLPROP, SOUR-WATER, PENG-ROBINSON.

FEED
MIX
COMP
COND
Valve
EVAP
Split
Purge
Reference model (ChemSep)

Ammonia refrigeration cycle

A single-stage vapor-compression refrigeration loop using ammonia — the classic industrial (rather than HFC) refrigerant — condensed to subcooled liquid, throttled through a valve, and superheated back to vapor in the evaporator before recycling (inspired by ChemSep's Refrigeration_Ammonia-30C reference case).

8 unit ops • COOLPROP

223 0

View & open
Sourwater
Stripsteam
liq
gas
gas
rich
SWS
Sourgas
Strippedwater
Illustrative refinery sour-water unit

Refinery sour water stripper (NH₃ + H₂S)

The standard refinery sour water stripper: sour water carrying ammonia and hydrogen sulfide is steam-stripped in a 10-stage column, sending both overhead as sour gas and returning stripped water fit for reuse. Runs on the new sour-water weak-electrolyte package, which is what makes the result meaningful — ammonia and H₂S suppress each other's volatility (ammonia raises pH and holds sulfide down as HS⁻; H₂S lowers pH and holds ammonia down as NH₄⁺), and heat reverses both, which is precisely why a stripper works. The two removals come out asymmetric for the real reason: H₂S strips essentially completely while ammonia, five orders of magnitude more soluble, is the duty that sets the steam rate.

5 unit ops • SOUR-WATER

134 0

View & open
K0
JT0
Cond0
Evap0
Cold-storage terminal, Rotterdam, Netherlands

Ammonia refrigeration (−30 °C)

A closed single-stage ammonia vapor-compression cycle serving a −30 °C load: compressor → ambient condenser → JT valve → evaporator. The charge is set via tear_specs; metrics give duty and work (COP ≈ 2). From the ChemSep casebook (Refrigeration_Ammonia-30C).

4 unit ops • PENG-ROBINSON

224 3

View & open
Makeup
Loopmix
Loophx
Qsplit
Feedhx
BED1
Qmix1
BED2
Qmix2
BED3
Chill
SEP
Ammonia
Purgesplit
Purge
Ammonia plant, Ludwigshafen, Germany

Quench-converter ammonia synthesis loop

The multi-bed quench converter BASF first installed in 1942, which displaced the tube-cooled converters before it, running inside a complete 200 bar synthesis loop. Ammonia synthesis is equilibrium-limited and exothermic, so the catalyst wants to run hot for rate and cool for equilibrium, and no single adiabatic bed can do both. The quench converter's answer is mechanical: split the loop gas, send 55% through the interchanger into bed 1 and inject the other 45% as cold shots between the beds, so each bed heats up adiabatically and each quench pulls it back down. What it computes: the sawtooth, 673 → 766 K in bed 1, quenched to 689 K and out at 760 K, quenched to 712 K and out at 766 K; 12.5 mol% ammonia at the converter exit, in the 12-18% band real quench converters deliver, at 20.9% nitrogen conversion per pass; 44.6 mol/s of 97.8% liquid ammonia off the 250 K separator; and argon and methane held at 3.3% and 4.2% in the loop by a 3% purge, with the recycle closed by a Wegstein tear. The acid test is the counterfactual: one adiabatic bed producing that same 12.51 mol% ammonia exit ends at 834.7 K — 562 C, past the sintering limit of promoted-magnetite catalyst — while the three-bed quench converter delivers the identical duty with a 766 K (493 C) peak.

15 unit ops • PENG-ROBINSON

76 0

View & open
Syngas
MIX
Reactor
Chill
SEP
NH3 Product
Split
Purge
Ammonia synthesis loop, Ludwigshafen, Germany

High-recycle ammonia loop (equation-oriented)

A tight, high-recycle ammonia synthesis loop built to show why a modern simulator solves recycles the way legacy sequential-modular tools can't. Fresh syngas (N₂ + 3H2, with argon inert) mixes with a large recycle, reacts to only ~10% per pass, chills so ammonia condenses out as product, and the unreacted gas recycles — a recycle-to-fresh ratio of ~5:1, with argon building up until a small purge balances it. Run this in Equation-Oriented mode (Solver menu > Mode > Equation-oriented). In the default sequential-modular mode the solver tears the recycle and iterates Wegstein ~78 times to close the loop; the equation-oriented solver instead makes every inter-unit stream a global unknown and closes all ~35 of them in one simultaneous Newton solve — the same simultaneous approach AVEVA SimCentral / gPROMS / IDAES use, and the reason tightly coupled recycles that crawl (or stall) in sequential-modular converge cleanly here.

8 unit ops • PENG-ROBINSON

224 2

View & open

Stop fighting legacy software. Build your first flowsheet in 60 seconds.