Reverse osmosis Process Flowsheets & Simulations
Explore 2 validated, solved Reverse osmosis simulation flowsheets in MaximaLabs — real components: water, nacl. Open any one directly in your browser.
Solved via: PENG-ROBINSON, BRINE.
Industrial water reuse: RO + membrane distillation to near-ZLD
A chemical-site water-reuse train of the kind large industrial water users build when the intake is salinising and freshwater is getting scarce: reverse osmosis makes reuse-grade water, the RO concentrate is warmed by low-grade waste heat and pushed further by membrane distillation, and the MD concentrate is crystallised to salt. Overall water recovery comes out at 94.9%. The point of the flowsheet is why MD is there at all. RO is pressure-driven, so its ceiling is osmotic pressure — and this feed hits that wall hard: at 25 bar the same 75% recovery is infeasible, and the model says so with a number rather than a shrug (osmotic pressure 27.2 bar against a 25 bar feed, a structured SPEC_THERMODYNAMICALLY_IMPOSSIBLE error, which is why the feed here runs at 45 bar). Membrane distillation is driven by a vapour-pressure difference instead, so only vapour crosses and there is no osmotic ceiling at all: it takes the RO concentrate from 2.0 mol% to 9.7 mol% salt, recovering 81% of the water RO had to leave behind, and its distillate is solvent-only. The waste-heat coupling is not decoration. At the RO concentrate's own 25 C the MD flux is about 1 kg/m2/h and the module is pointless; warmed to 60 C it runs at 21.5 kg/m2/h, inside the 10-50 kg/m2/h band real DCMD modules achieve. That is the entire commercial case for MD — it is a heat-driven process, so it is only cheap where low-grade heat is already being vented.
9 unit ops • PENG-ROBINSON
67 0
View & openRO desalination + ZLD
Seawater (real NaCl brine, Pitzer-electrolyte thermo) is pressurized and split in a reverse-osmosis membrane into fresh permeate and concentrate; a thermal brine concentrator (an evaporator effect) drives the concentrate the rest of the way to saturation — RO alone can't reach it, since retentate osmotic pressure would exceed any practical feed pressure — before a crystallizer closes the zero-liquid-discharge loop on solid NaCl. The membrane's recovery is bounded by the retentate's real osmotic pressure.
11 unit ops • BRINE
222 2
View & open