All unit operations
Electrostatic precipitator simulation
gas + solids -> clean gas + captured
Governing equations
The exact equations the solver works for a electrostatic precipitator — the same math shown in the app's "Theory" panel, not a black box.
- collection efficiency [0..1] — approaches 1 exponentially, which is why ESPs hit very high capture
- particle migration velocity toward the plate [m/s]
- total collecting-plate area [m²]
- gas volumetric flow [m³/s]
Parameters
migration_velocity [m/s, default 0.1], plate_area_m2 [default 200] (Deutsch-Anderson efficiency)