MaximaLabs
All unit operations

Thickener / clarifier simulation

slurry -> dense underflow + clarified overflow

Governing equations

The exact equations the solver works for a thickener / clarifier — the same math shown in the app's "Theory" panel, not a black box.

n˙s,under=Rn˙s,in,n˙l,under=n˙s,under1fsfs\dot n_{s,under}=R\,\dot n_{s,in},\quad \dot n_{l,under}=\dot n_{s,under}\frac{1-f_s}{f_s}
n˙over=n˙inn˙under    (clarified liquid + unrecovered fines)\dot n_{over}=\dot n_{in}-\dot n_{under}\;\;(\text{clarified liquid + unrecovered fines})

Parameters

solids_recovery [0..1 solids to underflow, default 0.98], underflow_solids_fraction [0..1 solids fraction of the dense underflow, default 0.55]; feed = solid + liquor inlets (Coe-Clevenger mass balance)

Example flowsheets that use it

Stop fighting legacy software. Build your first flowsheet in 60 seconds.