All unit operations
Thickener / clarifier simulation
slurry -> dense underflow + clarified overflow
Governing equations
The exact equations the solver works for a thickener / clarifier — the same math shown in the app's "Theory" panel, not a black box.
- solids recovery to the underflow [0..1]
- solids molar flow [mol/s]
- liquid molar flow [mol/s]
- solids fraction of the dense underflow — sets how much liquid must go with it
- overflow (clarified liquid + unrecovered fines) [mol/s]
Parameters
solids_recovery [0..1 solids to underflow, default 0.98], underflow_solids_fraction [0..1 solids fraction of the dense underflow, default 0.55]; feed = solid + liquor inlets (Coe-Clevenger mass balance)