MaximaLabs
All guides
Guemassa, Morocco (representative flowsheet)

How to simulate guemassa-type cobalt refinery (representative): arsenide leach, scorodite, cu ew, cyanex 272, co ew, coso4, ni(oh)2

A representative Bou-Azzer/Guemassa-type cobalt refinery, not Managem's plant. Managem's Bou-Azzer mine supplies most of the cobalt concentrate its Guemassa hydrometallurgical plants turn into cobalt cathodes, cobalt derivatives and nickel (managemgroup.com, read 2026-10-23), and La Vie Eco (30 December 2025, read) reports a cobalt sulphate unit there of up to 5,800 t/y, from Bou-Azzer metal, entering service in 2026. The plant's own flowsheet and operating figures are not public, so every plant number here is labelled representative. The feed is read from a source: the Bou Azzer concentrate Managem supplied for study, 91.9 g/kg Co, 598 As, 84.3 Fe, 17.5 Ni, 1.9 Cu and 8.1 S (Johnson et al., Hydrometallurgy 2020, Table 1), a skutterudite/loellingite arsenide. Its Fe:As molar ratio comes out 0.19, as that paper states, against about 1 needed to fix arsenic as scorodite. 0.80 kg/s of it (about 2,300 t/y of contained cobalt, the district's output in the same paper) is leached in sulfuric acid at 90 C (95% extraction and the even As(III)/As(V) split are representative inputs), giving a liquor of about 25 g/L As. The arsenic_precipitation unit then oxidises the As(III) and Fe(II) with 50% H₂O₂ (3.6 mol/s, the stoichiometric demand, drawn from the supply with the rest returned), tops the iron up with ferric sulfate to Fe:As 1.1 (5.5 mol/s Fe, more iron than the concentrate itself carries, which is why arsenide feeds are usually roasted to arsenic trioxide first), and doses lime to pH 1.8 at 90 C: 1.40 kg/s of scorodite and 1.92 kg/s of gypsum, 0.02 mg/L As left, on a scorodite solubility product of -26.67 at 90 C (Langmuir, Mahoney & Rowson's -25.83 at 25 C carried by the temperature dependence of Zhu, Nordstrom et al. 2017). The residue's equilibrium arsenic in TCLP fluid #1 (pH 4.93, 20 L/kg) is 0.03 mg/L against the 5 mg/L toxicity characteristic. A second stage takes the excess iron out as ferrihydrite at pH 4 with lime. Copper is plated potentiostatically (-0.05 V, plug flow, 92% removed), the liquor is neutralised to pH 5 with caustic, and Cyanex 272 at pH 5 (Liu et al. 2021 isotherms) takes all the cobalt and 0.4% of the nickel. The strip liquor, made up with fresh acid and 75% of the spent electrolyte (recycled), is split: 66% goes to cobalt sulphate, where water is removed (87.5%, a specified removal) and CoSO₄.7H2O crystallises at 30 C to Seidell's solubility (42.26 g CoSO₄ per 100 g water), the mother liquor recycled with a 5% bleed: 0.185 kg/s, about 5,826 t/y, at 95.2% purity with 5% mother liquor in the cake. The rest goes to cobalt electrowinning at 90% current efficiency and 3.2 V, which is 3.23 kWh/kg: the US Bureau of Mines measured 1.48 kWh/lb (3.26 kWh/kg) for cobalt from 75 g/L at 65 C, and about 90% current efficiency. 0.022 kg/s of cathode cobalt (about 692 t/y). Nickel is precipitated from the raffinate as Ni(OH)2 at pH 8.5. Copper is won as cathode, not as copper sulphate: at 1.9 g/kg in the concentrate it never approaches CuSO₄.5H2O saturation in this liquor. Bounds: the amorphous ferric arsenate constant is a 25 C value; no arsenate adsorption on ferrihydrite; no jarosite; the evaporation is a specified water removal (the brine property package carries dissolved cobalt as an inert solute, so a steam-driven effect would boil this liquor to dryness at one temperature) and its duty is not computed; the CoSO₄ solubility is in water, not in the acid mother liquor; the leach, the H₂O₂ utilisation, the copper cell, the splits and the SX flows are representative; the barren organic is not recycled.

Concentrate
Leach ACID
solid
acid
PLS
residue
Leach
Leach Residue
H2O2
Ferric Sulfate
LIME 1
liq
ox
Fe
lime
liq
As
xs
AS Scorodite
Scorodite Residue
Unused Reagents 1
LIME 2
liq
ox
Fe
lime
liq
As
xs
FE AS Polish
Ferric Arsenate Residue
Unused LIME 2
electrolyte
spent
cathode
gas
EW CU
Copper Cathode
CU CELL GAS
Caustic
liquor
reagent
out
excess
Neutralizer
Unused Caustic
CO Organic FEED
feed
solv
ext
raff
SX CO
Strip Liquor
feed
solv
ext
raff
Strip
Barren Organic
electrolyte
spent
cathode
gas
EW CO
Cathode Cobalt
Spent Electrolyte
CO CELL GAS
feed
clarified
sludge
NI Precip
Nickel Hydroxide
Barren Liquor
Strip MIX
CO Split
Spent Split
Sulph MIX
EVAP
EVAP Water
feed
solid
liq
CO Cryst
Cobalt Sulphate
ML Split
Mother Liquor Bleed
  1. 1
    Open the ready-made model

    Open the "Guemassa-type cobalt refinery (representative): arsenide leach, scorodite, Cu EW, Cyanex 272, Co EW, CoSO4, Ni(OH)2" model in the MaximaLabs workspace — no install, no license. It loads live on the canvas, ready to edit and run.

  2. 2
    Confirm the thermodynamics

    This process is modeled with the BRINE property package over water, h2so4, so4, cobalt_concentrate, co, ni, cu, fe2, fe3, h3aso3, h3aso4, h2o2, lime, ca, naoh, kerosene, o2, h2, cobalt_sulfate_heptahydrate — already selected, so the phase equilibrium and enthalpy are physically consistent from the first run.

  3. 3
    Review the flowsheet

    The flowsheet chains Leach, 2× FE AS Polish, 2× EW CO, Neutralizer, 2× Strip, NI Precip, 2× Sulph MIX, 3× ML Split, EVAP, CO Cryst. Every block is a real, solvable unit op you can reconfigure on the canvas.

  4. 4
    Run the simulation

    Click Run. The deterministic solver converges the material and energy balances (recycles included) and fills the live stream table — the AI never invents a number.

  5. 5
    Read the results and iterate

    Inspect the converged streams, tweak a spec, and re-run — or ask the AI copilot to explain a result or diagnose a failed solve in plain English.

What you'll build
Thermodynamics
BRINE
Components
water, h2so4, so4, cobalt_concentrate, co, ni, cu, fe2, fe3, h3aso3, h3aso4, h2o2, lime, ca, naoh, kerosene, o2, h2, cobalt_sulfate_heptahydrate
Unit operations
Leach2× FE AS Polish2× EW CONeutralizer2× StripNI Precip2× Sulph MIX3× ML SplitEVAPCO Cryst
Open this model in the workspace

Opens live on the canvas — free, no install.

Explore the model & flowsheet

Frequently asked questions

What does the Guemassa-type cobalt refinery (representative): arsenide leach, scorodite, Cu EW, Cyanex 272, Co EW, CoSO4, Ni(OH)2 model simulate?
A representative Bou-Azzer/Guemassa-type cobalt refinery, not Managem's plant. Managem's Bou-Azzer mine supplies most of the cobalt concentrate its Guemassa hydrometallurgical plants turn into cobalt cathodes, cobalt derivatives and nickel (managemgroup.com, read 2026-10-23), and La Vie Eco (30 December 2025, read) reports a cobalt sulphate unit there of up to 5,800 t/y, from Bou-Azzer metal, entering service in 2026. The plant's own flowsheet and operating figures are not public, so every plant number here is labelled representative. The feed is read from a source: the Bou Azzer concentrate Managem supplied for study, 91.9 g/kg Co, 598 As, 84.3 Fe, 17.5 Ni, 1.9 Cu and 8.1 S (Johnson et al., Hydrometallurgy 2020, Table 1), a skutterudite/loellingite arsenide. Its Fe:As molar ratio comes out 0.19, as that paper states, against about 1 needed to fix arsenic as scorodite. 0.80 kg/s of it (about 2,300 t/y of contained cobalt, the district's output in the same paper) is leached in sulfuric acid at 90 C (95% extraction and the even As(III)/As(V) split are representative inputs), giving a liquor of about 25 g/L As. The arsenic_precipitation unit then oxidises the As(III) and Fe(II) with 50% H₂O₂ (3.6 mol/s, the stoichiometric demand, drawn from the supply with the rest returned), tops the iron up with ferric sulfate to Fe:As 1.1 (5.5 mol/s Fe, more iron than the concentrate itself carries, which is why arsenide feeds are usually roasted to arsenic trioxide first), and doses lime to pH 1.8 at 90 C: 1.40 kg/s of scorodite and 1.92 kg/s of gypsum, 0.02 mg/L As left, on a scorodite solubility product of -26.67 at 90 C (Langmuir, Mahoney & Rowson's -25.83 at 25 C carried by the temperature dependence of Zhu, Nordstrom et al. 2017). The residue's equilibrium arsenic in TCLP fluid #1 (pH 4.93, 20 L/kg) is 0.03 mg/L against the 5 mg/L toxicity characteristic. A second stage takes the excess iron out as ferrihydrite at pH 4 with lime. Copper is plated potentiostatically (-0.05 V, plug flow, 92% removed), the liquor is neutralised to pH 5 with caustic, and Cyanex 272 at pH 5 (Liu et al. 2021 isotherms) takes all the cobalt and 0.4% of the nickel. The strip liquor, made up with fresh acid and 75% of the spent electrolyte (recycled), is split: 66% goes to cobalt sulphate, where water is removed (87.5%, a specified removal) and CoSO₄.7H2O crystallises at 30 C to Seidell's solubility (42.26 g CoSO₄ per 100 g water), the mother liquor recycled with a 5% bleed: 0.185 kg/s, about 5,826 t/y, at 95.2% purity with 5% mother liquor in the cake. The rest goes to cobalt electrowinning at 90% current efficiency and 3.2 V, which is 3.23 kWh/kg: the US Bureau of Mines measured 1.48 kWh/lb (3.26 kWh/kg) for cobalt from 75 g/L at 65 C, and about 90% current efficiency. 0.022 kg/s of cathode cobalt (about 692 t/y). Nickel is precipitated from the raffinate as Ni(OH)2 at pH 8.5. Copper is won as cathode, not as copper sulphate: at 1.9 g/kg in the concentrate it never approaches CuSO₄.5H2O saturation in this liquor. Bounds: the amorphous ferric arsenate constant is a 25 C value; no arsenate adsorption on ferrihydrite; no jarosite; the evaporation is a specified water removal (the brine property package carries dissolved cobalt as an inert solute, so a steam-driven effect would boil this liquor to dryness at one temperature) and its duty is not computed; the CoSO₄ solubility is in water, not in the acid mother liquor; the leach, the H₂O₂ utilisation, the copper cell, the splits and the SX flows are representative; the barren organic is not recycled.
Which thermodynamic method does it use?
The BRINE property package, over water, h2so4, so4, cobalt_concentrate, co, ni, cu, fe2, fe3, h3aso3, h3aso4, h2o2, lime, ca, naoh, kerosene, o2, h2, cobalt_sulfate_heptahydrate — already selected. You can switch the method on the canvas before running.
Which unit operations are in the flowsheet?
It chains Leach, 2× FE AS Polish, 2× EW CO, Neutralizer, 2× Strip, NI Precip, 2× Sulph MIX, 3× ML Split, EVAP, CO Cryst. Every block is a real, solvable unit operation you can reconfigure, add to, or remove.
Do I need to install software or buy a license?
No. Guemassa-type cobalt refinery (representative): arsenide leach, scorodite, Cu EW, Cyanex 272, Co EW, CoSO4, Ni(OH)2 runs entirely in your browser on MaximaLabs — free, no install, no license. Open the model to load it live and run the deterministic solver.

More guides like this

Guemassa, Morocco (representative flowsheet)

Guemassa-type cobalt refinery, roast-leach route (representative): roaster, white arsenic, calcine leach, scorodite polish, Cu EW, Cyanex 272, Co EW, CoSO4, Ni(OH)2

The guemassa-cobalt-refinery flowsheet with a de-arsenication roast in front of the leach, which is how arsenide concentrates are usually treated: the direct leach has to buy more iron than the concentrate carries to fix its arsenic as scorodite. Everything from the scorodite stage on is the same nodes as the direct-leach example. The concentrate is REPRESENTATIVE: the roasting example's mineralogy (12% skutterudite, 8% cobaltite, 30% arsenopyrite, 5% pyrite, 45% quartz) with nickel and copper as NiO and CuO at the Bou Azzer concentrate's Ni/Co and Cu/Co (Johnson et al. 2020), 1.40 kg/s dry with 6% moisture, sized to carry the direct-leach example's 73.5 g/s of cobalt. The fluidized-bed roaster at 700 C and 30% excess air (95% of each arsenide roasted, pyrite 98%, inputs) releases 3.90 MW and rejects 1.46 MW to its coils; the off-gas carries 6.32% SO₂. Cooled to 150 C, 0.46 kg/s of white arsenic condenses (98.84% of the arsenic in the gas, on Welch & Duschak's measured As₄O₆ vapour pressure); in all, 93.9% of the arsenic fed leaves as white arsenic, 1.1% stays in the gas, which goes to a product labelled 'to acid plant' (the acid plant is the roasting example's), and 5.0% stays in the calcine and dust, at 1.84% As. Calcine and dust are leached in sulfuric acid at 90 C, mineral by mineral (inputs: 95% of the Co₃O₄, NiO, CuO and unroasted sulfides and arsenides, 10% of the hematite; Co₃O₄ dissolving as Co(II) assumes a reductive leach whose reductant is not tracked), consuming 2.00 mol/s of acid. The liquor carries 978 mg/L As against 25,228 mg/L in the direct leach, and the iron the calcine dissolves puts its Fe:As at 1.82, so the scorodite stage buys no ferric iron (0.0 mol/s against 5.5 mol/s in the direct leach) and needs 0.18 mol/s of H₂O₂ (3.6), 3.60 mol/s of lime (11.18) and makes 0.05 kg/s of scorodite (1.40) and 0.61 kg/s of gypsum (1.92), leaving 0.03 mg/L As; its TCLP screen is 0.03 mg/L. The iron the scorodite does not need drops as ferrihydrite at pH 4 (0.021 kg/s). Downstream as in the direct-leach example: 95% of the copper plated, 0.5% of the nickel co-extracted by Cyanex 272, cobalt electrowon at 3.23 kWh/kg (0.022 kg/s of cathode), and CoSO₄.7H2O at 0.185 kg/s, about 5,826 t/y at 95.2% purity. Bounds: the roast conversions, dust carry-over, collection efficiency and leach fractions are inputs; skutterudite and cobaltite run on DFT heats of formation (see the roasting example); nickel and copper enter as oxides because the roaster has no Ni or Cu minerals, so the arsenic of the nickel arsenides a real Bou Azzer concentrate carries is missing; oxygen in the leach is not tracked; the SO₂ is not converted here.

Murrin Murrin nickel-cobalt laterite operation, Western Australia

Cobalt/nickel solvent extraction (D2EHPA)

A laterite leach liquor (Co/Ni/Mg in dilute sulfate solution) meets a D2EHPA-in-kerosene organic phase across a 20-stage countercurrent extraction circuit run at pH 5.2 — the real industrial operating window (e.g. Bulong, Murrin Murrin, Western Australia) that exploits the ~1 pH-unit gap between Co and Ni's D2EHPA extraction isotherms: Co extracts into the organic while Ni (and Mg gangue) are rejected to the raffinate. The loaded organic then meets fresh dilute-acid strip liquor across a 10-stage strip circuit at pH 1.0 (well below Co's isotherm), reversing the equilibrium to recover a concentrated cobalt strip liquor and regenerate barren organic. Real pH-isotherm chemistry throughout, not a fitted shortcut K_D.

Battery-recycling hydrometallurgy pilot plant (illustrative)

Battery cobalt recovery: leach, neutralize, D2EHPA Mn SX, Cyanex 272 Co SX, electrowinning

Spent NMC111 black mass is leached in sulfuric acid with the acid consumption tracked (lithium as Li₂SO₄, each transition metal as its sulfate), so the pregnant leach solution carries the residual free acid a real leach leaves. A neutralizer then titrates that liquor with 20 wt% caustic to pH 4.0 on the aqueous speciation: the caustic dose is solved, not assumed, and the heat of neutralization (55.8 kJ per mole of acid neutralized) warms the liquor; the caustic header is the supply, and what the titration does not take is returned. Two solvent-extraction circuits on the pH-isotherm chemistry follow, the common NMC arrangement: D2EHPA at pH 4.0 takes manganese into the organic while cobalt and nickel stay behind, and Cyanex 272 at pH 5.0 then takes cobalt and rejects nickel and lithium to the raffinate. The Cyanex 272 isotherms are one published measurement (Liu et al., Metals 11 (2021) 401: 0.4 M in ShellSol D70, 40 C, sulfate; pH50 cobalt 4.15, nickel 6.06), and the 1.9 pH-unit gap between them is why the cobalt organic carries about 0.6% of the nickel, against about 3% with D2EHPA at the same cobalt recovery. The loaded cobalt organic is stripped into a dilute sulfuric strip liquor, and that advance electrolyte goes to cobalt electrowinning: Faraday's law at a 90% current efficiency, 90% of the cobalt plated as cathode cobalt, the anode's oxygen and the 10% of the charge that evolves hydrogen reported as cell gas, and one mole of sulfuric acid regenerated per mole of cobalt plated.

Cobalt arsenide roasting, Bou-Azzer-type concentrate (representative)

Cobalt arsenide roasting: de-arsenication, white arsenic and acid-plant gas

A cobalt arsenide concentrate is roasted to drive its arsenic off as As₄O₆ vapour before the calcine is leached for cobalt; the arsenic is recovered from the gas as white arsenic and the sulfur goes on to a sulfuric acid plant. The concentrate is REPRESENTATIVE of a Bou-Azzer-type feed, not an assay: 5.0 kg/s dry of 12% skutterudite (CoAs₃), 8% cobaltite (CoAsS), 30% arsenopyrite (FeAsS), 5% pyrite and 45% quartz (5.3% Co, 27% As), with 6% moisture. The fluidized-bed roaster runs at 700 °C with 30% excess air; how far each mineral roasts is an input (95%, pyrite 98%). It balances every element and the energy on Robie & Hemingway (1995) and NBS (1982) formation enthalpies: the roast releases 14.16 MW, the bed rejects 5.35 MW to its cooling coils (autogenous; with no heat removed the products would leave at 1386 K), and the off-gas carries 6.33% SO₂, 4.88% O₂ and 1.79% As₄O₆. The cobalt leaves as Co₃O₄ because the gas's oxygen keeps it stable below 1169 K. 95% of the arsenic is volatilised and the calcine holds 1.88% As; 30% of the calcine is carried to the boiler as dust. The gas is then cooled to 150 °C, where As₄O₆'s vapour pressure over solid arsenic trioxide is 2.93 Pa (Welch & Duschak 1915, USBM Technical Paper 81, measured 100-300 °C): 99.84% of it condenses and a baghouse at 99% collection gives 1.67 kg/s of white arsenic, 98.84% of the arsenic in the gas. The same cooler run at 200 °C would recover 94.3% and at 250 °C 27.5%, which is why arsenic is collected cold. Cooling takes out 5.12 MW, 0.45 MW of it sublimation heat. Wet gas cleaning and drying remove the rest of the arsenic and the water, leaving 6.97% SO₂ for the converter, which oxidises 98% of it (one bed, an input) for the absorber.

Nashville, Tennessee, USA

Battery black-mass recycling: leach -> SX -> BPED -> LiOH crystallization

Spent-battery black mass (an NMC111-like LiNi1/3Mn1/3Co1/3O2 lump, sulfuric acid-leached at a screening-level yield/stoichiometry — see the stated scope) dissolves into a pregnant leach solution carrying Li/Co/Ni/Mn. A 15-stage D2EHPA solvent-extraction circuit (the same real pH-isotherm chemistry the co-ni-solvent-extraction example uses, operated at pH 7.5 — above every curated Co/Ni/Mn pH50 — so all three transition metals extract into the kerosene organic phase while Li, which has no curated D2EHPA isotherm, stays in the aqueous raffinate untouched) purifies the liquor before it ever reaches the lithium-recovery chemistry. A Faraday's-law bipolar-membrane electrodialysis (BPED) cell (the same real electrochemistry as the direct-lithium-extraction example, sized up for this liquor's larger Li flow) converts Li+ to LiOH, which an MSMPR crystallizer takes to battery-grade LiOH solid. Every step reuses an already-real, independently-tested unit op (,,,) chained into the one train none of them had been assembled into before.

Wet-process phosphoric acid plant (illustrative)

Wet-process phosphoric acid: electrochemical removal of copper and cadmium

Wet-process phosphoric acid (about 42 wt% H₃PO₄, 10 kg/s) carries the metals its phosphate rock brought in: iron, zinc, nickel, copper and the cadmium that limits how the acid may be used in fertilizer. Two flow-through electrochemical cells remove the two noble enough to plate from strong acid. The first holds its cathode at -0.05 V vs SHE: copper's Nernst potential sits far above that, so copper plates at its mass-transfer limit (plug-flow law, 99% removed) while zinc, nickel, iron and cadmium, whose potentials lie below the cathode, stay dissolved. The second cell runs at -0.55 V and is told that only cadmium plates: mass transfer alone would take 99.4% of it, but at that potential and 323 K the Nernst floor holds about 2.6e-5 mol/L in solution, so the solver reports the equilibrium-limited 91% instead. Each cell's current comes from the metal's partial current and the current efficiency you give it; the copper and cadmium currents regenerate phosphoric acid (one proton per dihydrogen-phosphate counter-ion), and the rest of the charge evolves hydrogen beside the anode's oxygen, which the cell gas reports, with a flammability warning.

Stop fighting legacy software. Build your first flowsheet in 60 seconds.