Urea synthesis loop from green ammonia and captured CO2 — a PENG-ROBINSON process flowsheet
Where green ammonia goes next. Ammonia and CO₂ react in a melt at 150 bar and 185 degC; only part of the CO₂ converts per pass, so the unconverted reagents are let down, stripped off and recycled, which is the whole reason a urea plant is a loop. Solved: 200 mol/s NH₃ and 100 mol/s CO₂ give 102.2 mol/s of melt at 96.2 mol% urea, 98.3 mol/s of urea (98% of the CO₂ fed, the rest lost with the 2% purge), on a 155 mol/s recycle. The reaction heat is NOT typed in from a handbook sentence: it is computed from formation enthalpies already in this tree — urea(s) -333.1 kJ/mol and water(l) -285.8 against ammonia(g) -45.6 and CO₂(g) -393.5 (CODATA/NIST values bundled with the MIT-licensed chemicals package; this repo's own NBS 1982 row for urea agrees to 410 J/mol, 0.12%) give -134.3 kJ/mol for crystal urea and liquid water, and the tree's own NBS dissolution row for urea (+12.3 kJ/mol at 3 H₂O) puts the melt basis the reactor actually produces at -122.0 kJ/mol, which is the value used.
Modeling assumptions & limitations
- 1And each is a measurement or a checked absence rather than a hedge:
- 2The TWO-STEP mechanism is not resolved — real synthesis forms ammonium carbamate exothermically and then dehydrates it endothermically, and ammonium carbamate's formation enthalpy is in neither this repo's bundled NBS rows nor the chemicals package (both checked, both return nothing), so splitting the heat between the steps would mean inventing the number that decides it; the overall reaction is exact and the split is not attempted.
- 3That lumping has a visible cost: this reactor must be COOLED by 19.2 MW to hold 185 degC, where a real urea reactor is close to adiabatic because the dehydration endotherm absorbs most of the carbamate exotherm. Of that 19.2 MW, 12.0 is the cited reaction heat (98.3 mol/s x 122 kJ/mol) and 7.2 is the streams' own enthalpy change — Peng-Robinson's model for a pseudocomponent urea in a dense melt, which is screening-grade. The balance closes exactly: duty = F.dh + extent x dH.
- 4The per-pass CO₂ conversion is a stated plant input, not a prediction. The equilibrium correlations for it (Frejacques, Mavrovic, Gorlovskii) and the 1933 carbamate-urea-water equilibrium data they are fitted to are in paywalled literature this environment cannot read, so nothing here predicts how conversion moves with the N/C ratio, the water content or the temperature.
- 5The feed is therefore STOICHIOMETRIC at N/C = 2, where a real plant runs 3 to 4 precisely because excess ammonia drives the equilibrium — an effect this model cannot show for the reason above. It also has no dedicated ammonia-recovery section, so an excess-ammonia feed simply accumulates until the purge balances it: measured, N/C 3.5 drives the recycle to 9,700 mol/s and the purge to 198 mol/s.
- 6The melt concentration is a specified-recovery water separator and NOT a flash, because the cubic gives urea a corresponding-states vapour pressure of 11.5 kPa at 408 K — above urea's own 406.5 K melting point, where it decomposes rather than boils — and that correlation is internally inconsistent with the bundled sublimation enthalpy (62.7 against 87.3 kJ/mol over 350-408 K). Flashed on it, two thirds of the urea left in the overhead. The number that would decide a real flash is not available.
- 7No biuret, the side product that limits reactor residence time, and the stripper is an equilibrium flash rather than a real stripper and carbamate condenser driven by stripping CO₂.
26 views 0 forks
- Rigorous PENG-ROBINSON thermodynamics, solved by the same engine every simulation runs on.
- 8 unit operations modeled: MIX, Synth, Letdown, Stripper, Recycle Split, Recycle PUMP, Concentrator, MELT SEP.
- Focus areas: Urea, Green ammonia, Recycle, Fertilizer.
- Thermodynamics
- PENG-ROBINSON
- Components
- ammonia, carbon_dioxide, urea, water
- Unit operations
- MIXSynthLetdownStripperRecycle SplitRecycle PUMPConcentratorMELT SEP
Opens in a new tab, loaded straight into the app — no setup.
Read the step-by-step guideReproduce this exact result from Python — the real client.get_example() → run_and_wait() path, not a mockup.
from flowsim.sdk import FlowSimClient
client = FlowSimClient()
example = client.get_example("urea-synthesis-loop")
sim = client.create_simulation(example["title"], example["flowsheet"])
result = client.run_and_wait(sim["id"])
print(result["status"]) # "converged"
streams = client.streams(sim["id"])Related models
Green urea synthesis
Green ammonia and captured CO₂ react over a single-pass stoichiometric reactor (2NH₃ + CO₂ ⇌ CO(NH₂)₂ + H₂O) at synthesis-loop conditions — the fertilizer step downstream of green ammonia. Screening fidelity: a real plant recycles the unconverted carbamate/excess ammonia to push per-pass yield well above this single-pass conversion; that recycle isn't modeled here.
Helium liquefaction (Linde-Hampson cycle)
A Joule-Thomson liquefaction loop: helium is compressed, aftercooled, precooled well below its ~40-51 K JT-inversion temperature, then throttled through a valve into a flash drum that draws off liquid helium while the cold vapor recycles back to the compressor suction — the same JT-cycle physics as the platform's LNG/refrigeration loops, run on a fluid whose inversion curve makes precooling mandatory before the throttle can cool it at all.
LOHC hydrogen release (methylcyclohexane dehydrogenation)
A liquid organic hydrogen carrier (LOHC) power train: methylcyclohexane (MCH) is preheated and catalytically dehydrogenated (MCH → toluene + 3H2, endothermic, equilibrium-limited to ~90% single-pass conversion) to release hydrogen for downstream power generation. A flash drum separates the H₂-rich gas from the liquid; a distillation column then recovers the unreacted MCH overhead and recycles it to the reactor feed, closing a real tight liquid recycle loop, while spent toluene leaves the bottoms (to be re-hydrogenated back to MCH off-site, closing the supply-chain loop — out of scope for this dehydrogenation-side flowsheet). Screening-fidelity note: MCH and toluene are genuinely close-boiling (relative volatility ~1.4 under this thermo package at column conditions), so the recycle carries real toluene along with the recovered MCH rather than a sharp cut — a production column would use more stages to purify it further; this shows the recycle topology and its convergence, not an optimized column design.
Recycle loop
A mixer/heater/splitter loop with a tear stream — exercises Wegstein recycle convergence.
Propane refrigeration cycle
A single-stage vapor-compression refrigeration loop: propane vapor is compressed, condensed to subcooled liquid, throttled through a valve, and superheated back to vapor in the evaporator before recycling — a small makeup feed and purge close the mass balance (inspired by ChemSep's Refrigeration_* reference cases).
Propane (R-290) heat pump heating a hydronic loop
A single-stage vapor-compression heat pump delivering heat to a space-heating water loop — the same cycle as a refrigerator, read from the hot end. Propane evaporates at 4.7 atm (273 K, an air- or ground-source evaporator at 0 °C), is compressed to 21 atm (condensing at 333 K, 60 °C) and condenses against the heating water in a real two-sided exchanger, so the delivered heat is a water stream you can read: 40 °C return warmed to 58 °C. A small makeup feed and purge close the refrigerant mass balance around the recycle, as in the refrigeration examples. Two numbers define the machine: 74 kW delivered for 21 kW of compressor work, a heating COP of 3.5 — 63% of the Carnot limit for this 60 K lift at the compressor's 0.75 isentropic efficiency. Read COP on the flowsheet as the user variable cop_heating, or sweep the condensing pressure: from 18 to 27 atm the COP falls 3.8 → 3.1 as the lift grows, the trade every heat pump makes between water temperature and electricity. Honest scope: the compressor is a fixed isentropic efficiency, the condenser outlet is a specified subcooling, and there is no defrost, part-load or refrigerant-charge model. Below ~18 atm the specified 326 K condenser outlet sits above saturation and the cycle stops condensing — the sweep starts where the physics does.