Arsenic trioxide condenser (cooler + baghouse) simulation
roaster gas -> cleaned gas, crude As2O3 product
Governing equations
The exact equations the solver works for a arsenic trioxide condenser (cooler + baghouse) — the same math shown in the app's "Theory" panel, not a black box.
- As4O6 mole fraction in the outlet gas [-]
- As4O6 vapour pressure over solid As2O3 [Pa]
- gas pressure [Pa]
- As4O6 vapour pressure [Pa]
- fit constant, 70.339 (Welch & Duschak 1915) [-]
- fit constant, 15963 [K]
- fit constant, -5.2151 [-]
- gas outlet temperature [K]
- arsenic recovered to the product [-]
- collection efficiency of the baghouse [-]
- As4O6 in the gas [mol/s]
- As4O6 left in the gas as vapour [mol/s]
Parameters
roaster gas cooled to a set temperature; As4O6 above its vapour pressure over solid As2O3 (Welch & Duschak 1915, USBM TP 81, 100-300 C) condenses and is collected. temperature [K] (required, gas outlet); collection_efficiency [-] (fraction of the condensed fume and of any dust captured, default 1 = ideal baghouse); pressure_drop [Pa] (default 0). Reports arsenic recovery (and at 100-250 C), the outlet As2O3 in mg/Nm3, crude As2O3 grade, the vapour pressure and the sublimation heat