Cooling-tower blowdown treatment — lime dosing and what it will not remove
The stream cooling-water-utility-circuit sends to effluent, treated. Concentrated blowdown (4 cycles on a hard makeup, plus zinc from a corrosion-inhibitor programme) is dosed with lime to pH 10.5, and the metals that can drop as hydroxides do.
A separate flowsheet on purpose. This runs on the brine electrolyte package with the ions as real components; the cooling loop runs on steam with water alone. Carrying hardness as flowsheet components changes the thermodynamics of every stream it touches, so the loop keeps its water model and the treatment plant gets the one it needs — which is also how the two are engineered and operated in a real plant.
The result is mostly a lesson in what hydroxide precipitation cannot do. Magnesium goes from 2100 to 10 ppm-equivalent (99.5% removed) and zinc is essentially complete, leaving a sludge that is 91% Mg(OH)2 and 9% Zn(OH)2. Calcium does not move at all — it enters at 0.0042 mole fraction and leaves at 0.0042. That is correct, not a failure to converge: Ca(OH)2 is far too soluble to precipitate at this pH, and removing calcium needs carbonate — soda-ash softening — which is a different reagent and a different chemistry from the one dosed here. A treatment report claiming lime alone softens a blowdown is describing something this model will not reproduce.
Sulfate likewise passes straight through: it leaves with the clarified water, which is why blowdown salinity is a discharge-consent question rather than something a precipitation stage fixes.
Bounded: equilibrium Ksp at a dosed pH (see thermo/electrolytes.py), with no self-consistent pH from the metal hydrolysis itself, a dilute-liquor volume estimate, and B-dot activities. The lime reagent is a circuit condition rather than a tracked feed, and the gypsum a real lime circuit throws is not modelled. Sludge dewatering is absent deliberately: the precipitator's solid outlet carries no entrained water, so a thickener placed after it would be splitting a dry stream and reporting a 'recovered water' that is 100% hydroxide.
The flowsheet
The solved topology — every unit op's real duty, conversion, or split, read straight off a genuine converged solve.
The stream table