LNG front end and storage: guard beds, tank boil-off, driver limit
The parts of a 5.2 Mtpa LNG train that are not the cold box, and the four questions they answer that no bulk unit can — at real capacity, so the vessel sizes and duties are ones an engineer can check against their own plant. Guard beds: a sulfur-carbon bed takes mercury from 200 to 0.01 µg/Nm³ — the brazed-aluminium limit, because mercury attacks the plate-fin cold box by liquid-metal embrittlement — on a 4.8 m x 6.6 m bed with 4.2 years of life from a capacity balance — inside the 3-5 year window these non-regenerable beds are actually replaced on, which is what a turnaround plan needs. A 4A molecular sieve then dries the gas to 0.1 ppmv, the only route to a cryogenic water spec (a glycol contactor tops out near a −30 °C dew point), on a 4.9 m x 5.1 m bed running a 13.8 h cycle for 1.3 MW of regeneration duty. Storage: the LNG goes to a tank whose boil-off rate comes from a 0.05%/day guarantee but whose boil-off composition comes from a real equilibrium flash — and that is the interesting part, because the vapour leaves at ~11 mol% nitrogen against 1.1% in the feed. Nitrogen and methane are far more volatile at 113 K, so the boil-off is light and the stored liquid weathers heavier: nobody specified that, the flash found it. Recondensing: the boil-off goes back into the send-out LNG rather than to a flare, and the unit reports the LNG:BOG ratio (1999) against the minimum the energy balance demands (3.8), which is the constraint a terminal is actually operated against. The driver: a gas turbine burning plant fuel gas, rated 97.5 MW at ISO conditions, delivers only 84.5 MW at 35 °C — 5.5 MW short of its 90 MW refrigeration load, and flagged as such. That derate is computed from two physical effects (a fixed-geometry compressor swallows a fixed volume so mass flow follows air density, and hotter air costs more to compress), not from a vendor curve, and it comes out at 0.66%/K — mid-band for industrial machines. It is why a tropical LNG train makes less product in summer. Honesty notes: (1) liquefaction here is a plain cooler standing in for a refrigeration train — the real C3MR cold box is 'c3mr-lng-liquefaction', and this showcase is about what surrounds it; (2) mercury is a unit-op PARAMETER in µg/Nm³, not a thermo component, because at 1e-9 mole fraction it is meaningless to an equation of state; (3) the guard bed is a capacity model, not a breakthrough model, and the sieve is an equilibrium design model, not a dynamic one; (4) the tank is well-mixed and steady-state — for what happens when that assumption fails, see the LNG-rollover analysis tool.
The flowsheet
The solved topology — every unit op's real duty, conversion, or split, read straight off a genuine converged solve.
The stream table
Every stream's flow, temperature, pressure, and composition — real converged numbers, not placeholders.