Rankine steam power cycle (pump -> boiler -> turbine -> condenser)
The classic steam power cycle behind most of the world's electricity, on the rigorous IAPWS-97 steam properties. Feedwater is pressurized by a boiler-feed pump, fired to superheated steam in the boiler, expanded through a steam turbine to make shaft power, then condensed back to water in the surface condenser. The four Rankine components appear in order, and the numbers are the real thermodynamic ones: at 60 bar / 500 degC steam expanding to a 0.1-bar condenser vacuum the turbine makes ~18 MW of shaft work at 85% isentropic efficiency, the exhaust leaves the turbine as wet steam (~92% quality, the classic low-pressure blade-erosion concern), the condenser rejects ~40 MW to cooling water, and the feed pump costs only ~0.15 MW (the small back-work ratio that makes the Rankine cycle practical, since pressurizing a liquid is nearly free next to expanding a gas). Cycle thermal efficiency comes out ~28%. Every property (the superheat enthalpy, the isentropic expansion endpoint, the exhaust steam quality) is the real IAPWS steam-table value, not a correlation. Honesty notes: an open (once-through) view of the cycle rather than a physically closed loop (a real plant recirculates the condensate); no reheat or feedwater regeneration stage (a single expansion, no extraction), so the efficiency is the simple ideal-cycle figure, not a supercritical/reheat station's ~45%.