BTX separation via dividing-wall column — a PENG-ROBINSON process flowsheet
Benzene/toluene/ethylbenzene split into three purified products by a single rigorous dividing-wall column (prefractionator + two coupled main columns) instead of two ordinary columns in series — the thermally-coupled route real DWC retrofits use.
344 views 0 forks
- Rigorous PENG-ROBINSON thermodynamics, solved by the same engine every simulation runs on.
- 1 unit operations modeled: DWC.
- Focus areas: Dividing-wall column, BTX, Peng-Robinson.
- Thermodynamics
- PENG-ROBINSON
- Components
- benzene, toluene, ethylbenzene
- Unit operations
- DWC
Opens in a new tab, loaded straight into the app — no setup.
Read the step-by-step guideReproduce this exact result from Python — the real client.get_example() → run_and_wait() path, not a mockup.
from flowsim.sdk import FlowSimClient
client = FlowSimClient()
example = client.get_example("btx-dividing-wall")
sim = client.create_simulation(example["title"], example["flowsheet"])
result = client.run_and_wait(sim["id"])
print(result["status"]) # "converged"
streams = client.streams(sim["id"])Related models
NGL fractionation: single-shell Petlyuk dividing-wall column
A natural-gas-liquids cut (ethane / propane / n-butane) split into three on-spec products by ONE thermally-coupled dividing-wall column instead of two columns in series. This uses the native Petlyuk unit op: a prefractionator whose reflux and boilup are supplied by the main column (the single condenser + single reboiler), solved by an outer Wegstein loop that converges the bidirectional vapor/liquid coupling to self-consistency — the coupling legacy sequential-modular solvers approximate with two connected columns whose recycle fails to converge.
DME synthesis via reactive distillation
Methanol dehydrates to dimethyl ether over the reactive stages of a column — reaction and separation in one shell, pulling DME overhead while unconverted methanol and water leave the bottoms (Peng-Robinson EoS avoids the missing UNIFAC group-decomposition for ethers that blocks this under an activity-coefficient package). The conversion is 78%, not 80%: with the distillate drawing 40% of the feed, an 80% conversion makes exactly the 4 mol/s of DME the distillate takes, so it would demand a perfectly pure DME overhead and DME-free bottoms, a split no finite column makes. The stages near the condenser hold almost no methanol, so the reaction runs where the methanol is, on the feed and stripping trays.
BTX aromatics train
Benzene / toluene / p-xylene split in a two-column train — 99+% purity on all three products. From the ChemSep casebook (CScasebook_BTX).
Reformate splitter via dividing-wall column
A refinery catalytic-reformer stream (benzene/toluene/o-xylene plus a non-aromatic n-heptane proxy) is split into three purified aromatics cuts by a single thermally-coupled dividing-wall column instead of two ordinary columns in series — the same DWC economics as the BTX example, applied to a genuine reformate splitter duty. Dejanovic, Matijasevic, Jansen, Olujic, "Designing a Packed Dividing Wall Column for an Aromatics Processing Plant," Ind. Eng. Chem. Res. 2011, 50, 5680.
LNG front end and storage: guard beds, tank boil-off, driver limit
The parts of a 5.2 Mtpa LNG train that are not the cold box, and the four questions they answer that no bulk unit can — at real capacity, so the vessel sizes and duties are ones an engineer can check against their own plant. Guard beds: a sulfur-carbon bed takes mercury from 200 to 0.01 µg/Nm³ — the brazed-aluminium limit, because mercury attacks the plate-fin cold box by liquid-metal embrittlement — on a 4.8 m x 6.6 m bed with 4.2 years of life from a capacity balance — inside the 3-5 year window these non-regenerable beds are actually replaced on, which is what a turnaround plan needs. A 4A molecular sieve then dries the gas to 0.1 ppmv, the only route to a cryogenic water spec (a glycol contactor tops out near a −30 °C dew point), on a 4.9 m x 5.1 m bed running a 13.8 h cycle for 1.3 MW of regeneration duty. Storage: the LNG goes to a tank whose boil-off rate comes from a 0.05%/day guarantee but whose boil-off composition comes from a real equilibrium flash — and that is the interesting part, because the vapour leaves at ~11 mol% nitrogen against 1.1% in the feed. Nitrogen and methane are far more volatile at 113 K, so the boil-off is light and the stored liquid weathers heavier: nobody specified that, the flash found it. Recondensing: the boil-off goes back into the send-out LNG rather than to a flare, and the unit reports the LNG:BOG ratio (1999) against the minimum the energy balance demands (3.8), which is the constraint a terminal is actually operated against. The driver: a gas turbine burning plant fuel gas, rated 97.5 MW at ISO conditions, delivers only 84.5 MW at 35 °C — 5.5 MW short of its 90 MW refrigeration load, and flagged as such. That derate is computed from two physical effects (a fixed-geometry compressor swallows a fixed volume so mass flow follows air density, and hotter air costs more to compress), not from a vendor curve, and it comes out at 0.66%/K — mid-band for industrial machines. It is why a tropical LNG train makes less product in summer.
Gas-condensate LNG train: condensate, LPG and LNG
The LNG plant that is also a liquids plant, at real capacity: this is one 4.4 Mtpa train (a two-train plant is two of these), not a scaled-down sketch. A condensate-rich field arrives by trunkline as a two-phase stream: the slug catcher drops ~20 mol% of it out as raw condensate before a single molecule reaches the cold end, and the plant then runs two trains side by side off one feed. Liquids: the raw condensate is let down to an MP flash that strips the dissolved methane (without it the stabilizer's shortcut total condenser tries to condense methane at 8 bar, which is not a real stabilizer overhead), then stabilized to a C₅/C₆ product. Gas: sweetened and dried, chilled to 245 K to knock out an NGL cut, and the NGL demethanized and split by a deethanizer / depropanizer / debutanizer sequence into commercial propane (~98 mol%) and butane (~98 mol%) LPG plus a natural-gasoline bottoms. LNG: the lean gas goes to the same APCI C3MR cold end as the 'c3mr-lng-liquefaction' showcase — propane precool, mixed-refrigerant MCHE to 120 K, JT letdown to a 1.5 bar end-flash drum. Five sold products come out of one flowsheet, each a stream the solver computed. Watch the end-flash boil-off: it leaves at ~13 mol% nitrogen against 1 mol% in the feed, because the flash drum is where an LNG train actually rejects its nitrogen — nobody specified that, the flash found it. Dehydration is the real molecular-sieve bed, not a stand-in: a 4A sieve sized by length-of-unused-bed, which is what actually takes the gas to the <=0.1 ppmv the cold box needs — 95 t of sieve on a 5.5 x 5.5 m bed, a 17.5 h cycle and 1.4 MW of regeneration duty, with 0.47 bar of Ergun pressure drop. The AGRU spec is checked against the physics rather than assumed: 99.9% CO₂ removal leaves 33 ppmv, and at the coldest point in the train (115.9 K) the solid-CO₂ solubility limit is 232 ppmv on the measured-data basis — a 7x margin, so the sweetening spec demonstrably clears freeze-out instead of merely looking tight.