MaximaLabs
All unit operations

CCD washer (counter-current decantation) simulation

residue solids + liquor + wash water -> washed solids + pregnant liquor

Governing equations

The exact equations the solver works for a ccd washer (counter-current decantation) — the same math shown in the app's "Theory" panel, not a black box.

funder=R1RN+11    (R1),1N+1    (R=1)    (counter-current washing)f_{under} = \frac{R-1}{R^{N+1}-1}\;\;(R\neq1),\quad \frac{1}{N+1}\;\;(R=1)\;\;(\text{counter-current washing})
recovery=1funder,R=Wwash/Lunder\text{recovery} = 1 - f_{under},\quad R = W_{wash}/L_{under}
funderf_{under}
fraction of feed solute remaining with the washed solids [0..1]
NN
number of counter-current washing (thickener) stages
RR
wash ratio — wash liquid per retained underflow liquid
WwashW_{wash}
wash-solvent flow [mol/s]
LunderL_{under}
liquor retained in the underflow [mol/s]

Parameters

n_stages [default 5], underflow_liquor_ratio [mol liquid per mol solid, default 2.0], solvent [wash medium id, default water], solids_recovery [default 1.0]; optional solute_components [list]

Example flowsheets that use it