source — no material stream; reports a power_w metric

Governing equations

The exact equations the solver works for a solar pv array — the same math shown in the app's "Theory" panel, not a black box.

Pdc=PratedGGstc[1+γ(TcellTstc)](PVWatts)P_{dc} = P_{rated}\,\frac{G}{G_{stc}}\left[1+\gamma\,(T_{cell}-T_{stc})\right]\quad(\text{PVWatts})
Pac=PdcfderateP_{ac} = P_{dc}\cdot f_{derate}
PdcP_{dc}
DC array power output [W]
PratedP_{rated}
nameplate DC capacity at STC [W]
GG
plane-of-array irradiance [W/m^2]
GstcG_{stc}
1000 W/m^2 (STC reference)
γ\gamma
temperature coefficient of power [%/C, negative]
TcellT_{cell}
cell temperature [C]
TstcT_{stc}
25 C (STC reference)
fderatef_{derate}
system-loss derate factor [0-1]
PacP_{ac}
reported AC power [W]

Parameters

rated_power_w [W, DC nameplate at STC], irradiance_w_m2 [W/m^2, plane-of-array]; optional cell_temperature_c [default 25], temp_coeff_pct_per_c [default -0.40], system_derate [0-1, default 0.86]. No material stream — reports power_w.