Governing equations
The exact equations the solver works for a virus filter — the same math shown in the app's "Theory" panel, not a black box.
- cumulative throughput [L/m^2]
- capacity [L/m^2]
- clean-filter flux [LMH]
- required membrane area [m^2]
- batch volume [L]
- available process time
Parameters
v_max [L/m^2 capacity, from a Vmax trial], initial_flux [LMH, clean filter]. Optional: batch_time [s], area [m^2 installed — checks rather than sizes], product_recovery [default 0.98].