TEG natural gas dehydration — a PENG-ROBINSON process flowsheet
Wet natural gas is contacted counter-currently with lean triethylene glycol (TEG) in an absorber, pulling water vapor into the glycol to meet a pipeline water spec; the rich glycol is then let down in pressure and regenerated in two flashes — the first flashes off the bulk of the co-absorbed methane, the second (hot) flash boils the absorbed water off the now nearly gas-free glycol, leaving hot lean glycol bottoms (its recycle back to the absorber is reported as a product, the same open-loop simplification used elsewhere in this library). Water is the most common undesirable natural-gas impurity — it forms hydrates that plug valves and fittings once the gas is compressed or cooled.
166 views 2 forks
- Rigorous PENG-ROBINSON thermodynamics, solved by the same engine every simulation runs on.
- 3 unit operations modeled: Contactor, Letdown, 2× Regen.
- Focus areas: Glycol dehydration, Absorption, Natural gas treating.
- Thermodynamics
- PENG-ROBINSON
- Components
- methane, water, triethylene_glycol
- Unit operations
- ContactorLetdown2× Regen
Opens in a new tab, loaded straight into the app — no setup.
Read the step-by-step guideReproduce this exact result from Python — the real client.get_example() → run_and_wait() path, not a mockup.
from flowsim.sdk import FlowSimClient
client = FlowSimClient()
example = client.get_example("teg-natural-gas-dehydration")
sim = client.create_simulation(example["title"], example["flowsheet"])
result = client.run_and_wait(sim["id"])
print(result["status"]) # "converged"
streams = client.streams(sim["id"])Related models
Perry Ch.13 Example 2: lean-oil absorber
Simple absorber recovering butane and pentane from a process gas into a lean-oil (n-dodecane) absorbent, from Chapter 13 of Perry's Chemical Engineers' Handbook.
Perry Ch.13 Example 5: two-step absorber with intercooling
Two absorption stages in series with intercooling between them (removing the heat of absorption, which otherwise raises K-values and hurts recovery) to maximize LPG recovery, from Chapter 13 of Perry's Chemical Engineers' Handbook.
Acetone from isopropanol dehydrogenation
Endothermic gas-phase dehydrogenation of isopropanol (IPA) to acetone, after Luyben (Ind. Eng. Chem. Res. 2011, 50, 1206). The H₂-rich reactor off-gas is scrubbed with water to recover the acetone before venting, then a column splits acetone from the water/unreacted-IPA absorbent.
CO2 removal from syngas (Rectisol-style physical solvent)
A CO₂-laden syngas stream from gasification/reforming (H₂/CO with 25% CO₂, the actual Rectisol duty — scrubbing raw syngas ahead of methanol/ammonia synthesis, not treating pipeline natural gas) is sweetened by a cold-methanol physical-solvent absorber (chosen because chemical amine reactions aren't modeled here) down toward synthesis-loop spec, then the rich solvent is regenerated by a pressure letdown into a second flash that flashes the bulk of the absorbed CO₂ back off — the same letdown-valve-plus-flash regeneration pattern used for HDA's and methanol synthesis's own dissolved-gas trains. No solvent recycle loop (an honest simplification: the regenerated solvent is reported as a product stream rather than closed back onto the absorber feed). From the ChemSep casebook (CO₂ removal from natural gas), adapted to Rectisol's real syngas duty.
LNG front end and storage: guard beds, tank boil-off, driver limit
The parts of a 5.2 Mtpa LNG train that are not the cold box, and the four questions they answer that no bulk unit can — at real capacity, so the vessel sizes and duties are ones an engineer can check against their own plant. Guard beds: a sulfur-carbon bed takes mercury from 200 to 0.01 µg/Nm³ — the brazed-aluminium limit, because mercury attacks the plate-fin cold box by liquid-metal embrittlement — on a 4.8 m x 6.6 m bed with 4.2 years of life from a capacity balance — inside the 3-5 year window these non-regenerable beds are actually replaced on, which is what a turnaround plan needs. A 4A molecular sieve then dries the gas to 0.1 ppmv, the only route to a cryogenic water spec (a glycol contactor tops out near a −30 °C dew point), on a 4.9 m x 5.1 m bed running a 13.8 h cycle for 1.3 MW of regeneration duty. Storage: the LNG goes to a tank whose boil-off rate comes from a 0.05%/day guarantee but whose boil-off composition comes from a real equilibrium flash — and that is the interesting part, because the vapour leaves at ~11 mol% nitrogen against 1.1% in the feed. Nitrogen and methane are far more volatile at 113 K, so the boil-off is light and the stored liquid weathers heavier: nobody specified that, the flash found it. Recondensing: the boil-off goes back into the send-out LNG rather than to a flare, and the unit reports the LNG:BOG ratio (1999) against the minimum the energy balance demands (3.8), which is the constraint a terminal is actually operated against. The driver: a gas turbine burning plant fuel gas, rated 97.5 MW at ISO conditions, delivers only 84.5 MW at 35 °C — 5.5 MW short of its 90 MW refrigeration load, and flagged as such. That derate is computed from two physical effects (a fixed-geometry compressor swallows a fixed volume so mass flow follows air density, and hotter air costs more to compress), not from a vendor curve, and it comes out at 0.66%/K — mid-band for industrial machines. It is why a tropical LNG train makes less product in summer.
Gas-condensate LNG train: condensate, LPG and LNG
The LNG plant that is also a liquids plant, at real capacity: this is one 4.4 Mtpa train (a two-train plant is two of these), not a scaled-down sketch. A condensate-rich field arrives by trunkline as a two-phase stream: the slug catcher drops ~20 mol% of it out as raw condensate before a single molecule reaches the cold end, and the plant then runs two trains side by side off one feed. Liquids: the raw condensate is let down to an MP flash that strips the dissolved methane (without it the stabilizer's shortcut total condenser tries to condense methane at 8 bar, which is not a real stabilizer overhead), then stabilized to a C₅/C₆ product. Gas: sweetened and dried, chilled to 245 K to knock out an NGL cut, and the NGL demethanized and split by a deethanizer / depropanizer / debutanizer sequence into commercial propane (~98 mol%) and butane (~98 mol%) LPG plus a natural-gasoline bottoms. LNG: the lean gas goes to the same APCI C3MR cold end as the 'c3mr-lng-liquefaction' showcase — propane precool, mixed-refrigerant MCHE to 120 K, JT letdown to a 1.5 bar end-flash drum. Five sold products come out of one flowsheet, each a stream the solver computed. Watch the end-flash boil-off: it leaves at ~13 mol% nitrogen against 1 mol% in the feed, because the flash drum is where an LNG train actually rejects its nitrogen — nobody specified that, the flash found it. Dehydration is the real molecular-sieve bed, not a stand-in: a 4A sieve sized by length-of-unused-bed, which is what actually takes the gas to the <=0.1 ppmv the cold box needs — 95 t of sieve on a 5.5 x 5.5 m bed, a 17.5 h cycle and 1.4 MW of regeneration duty, with 0.47 bar of Ergun pressure drop. The AGRU spec is checked against the physics rather than assumed: 99.9% CO₂ removal leaves 33 ppmv, and at the coldest point in the train (115.9 K) the solid-CO₂ solubility limit is 232 ppmv on the measured-data basis — a 7x margin, so the sweetening spec demonstrably clears freeze-out instead of merely looking tight.