ZLD Process Flowsheets & Simulations

Explore 2 validated, solved ZLD simulation flowsheets in MaximaLabs — real components: water, nacl. Open any one directly in your browser.

Solved via: PENG-ROBINSON.

RO FEED
RO
Reuse Water
Waste HEAT
MD
MD Distillate
feed
solid
liq
Cryst
SALT
Brine
Chemical production site, Port of Antwerp

Industrial water reuse: RO + membrane distillation to near-ZLD

A chemical-site water-reuse train of the kind large industrial water users build when the intake is salinising and freshwater is getting scarce: reverse osmosis makes reuse-grade water, the RO concentrate is warmed by low-grade waste heat and pushed further by membrane distillation, and the MD concentrate is crystallised to salt. Overall water recovery comes out at 94.9%. The point of the flowsheet is why MD is there at all. RO is pressure-driven, so its ceiling is osmotic pressure — and this feed hits that wall hard: at 25 bar the same 75% recovery is infeasible, and the model says so with a number rather than a shrug (osmotic pressure 27.2 bar against a 25 bar feed, a structured SPEC_THERMODYNAMICALLY_IMPOSSIBLE error, which is why the feed here runs at 45 bar). Membrane distillation is driven by a vapour-pressure difference instead, so only vapour crosses and there is no osmotic ceiling at all: it takes the RO concentrate from 2.0 mol% to 9.7 mol% salt, recovering 81% of the water RO had to leave behind, and its distillate is solvent-only. The waste-heat coupling is not decoration. At the RO concentrate's own 25 C the MD flux is about 1 kg/m2/h and the module is pointless; warmed to 60 C it runs at 21.5 kg/m2/h, inside the 10-50 kg/m2/h band real DCMD modules achieve. That is the entire commercial case for MD — it is a heat-driven process, so it is only cheap where low-grade heat is already being vented.

9 unit ops • PENG-ROBINSON

11 0

View & open
Effluent
RO
EDI
Ultrapure
Brine MIX
Waste HEAT
MD
MD Distillate
feed
solid
liq
Cryst
SALT
Brine
Chemical production site, Port of Antwerp

Site water reuse: RO + EDI polish + MD to near-ZLD

The full hybrid a large chemical site builds when it is reusing its own effluent rather than buying river water: reverse osmosis does the bulk desalting, electrodeionisation polishes the permeate to boiler-feed quality, and the RO concentrate is warmed by waste heat and pushed to salt by membrane distillation and a crystalliser. It is the companion to industrial-water-reuse-ro-md-zld, which stops at reuse-grade water; the delta here is the polishing leg, and it is a genuinely different technology rather than a tighter membrane. Why EDI and not more RO. RO is pressure-driven and pushes water, so its energy scales with the volume produced. Electrodialysis drags ions out under a field and the water never crosses, so its energy scales with the salt removed — which is why it is hopeless on seawater and excellent on an RO permeate that is already 99% desalted. This model shows that rather than asserting it: at the same stack and current the moles removed are fixed by Faraday's law regardless of how salty the feed is. The reason the polisher is resin-filled is the interesting part. Plain electrodialysis has a limiting current density proportional to the diluate concentration, so as the water approaches pure the boundary layer runs out of ions to deliver and the salt flux plateaus — ED cannot reach ultrapure at any voltage, and the voltage runs away as the water stops conducting. Packing the diluate compartment with ion-exchange resin fixes both: the resin carries the current, and the water splitting that occurs above the classical limiting current — a fault in a solution-filled stack, causing a pH excursion and scale — is exactly what regenerates the resin in place. That is why an EDI polisher needs no chemical regeneration, and why the same operating point means opposite things in the two stacks.